Edit page title Teledyne LeCroy - 串行数据 - QPHY-USB4-TX-RX
Edit meta description Teledyne LeCroy 是示波器、协议分析仪和相关测试和测量解决方案的领先供应商,使各行各业的公司能够设计和测试所有类型的电子设备。

Close edit interface
">
示波器 电子测试设备
协议分析解决方案
模块化数据采集 传感器和校准器 SSD 和 CXL 存储设备测试
  • Request a Quote
  • Contact Us
  • ">

    登录到您的
    Teledyne Lecroy 帐户

    登陆
    产品中心
    软件选项
    ">

    QPHY-USB4-TX-RX

    QualiPHY 自动化 USB4™(通用串行总线 4)物理层 (PHY) 测试符合 USB-IF USB4 和 Thunderbolt 3 CTS(一致性测试规范)通过 USB Type-C® 连接器。 Teledyne 力科 LabMaster SDA 10 Zi-A 示波器, WavePulser 40iX 高速互连分析仪和 Anritsu MP1900A R BERT(误码率测试仪)组成一个综合系统,可提供 USB4 测试工程师提供集成的电气测试解决方案。

    探索QPHY-USB4-TX-RX 向下箭头
    产品标题图片
    ""

    QPHY-USB4-TX-RX test software controls the Oscilloscope, BERT, and test controller to perform parametric, jitter, and eye compliance tests on the on the transmitters (Tx); and calibrating the stressed eye and performing BER measurements on the receivers (Rx). it first provides a step-by-step guide of how test system needs to be connected to correctly test the device. It then automatically configures the instrument and DUT settings and features, performs the test, and records the results in a compliance test report.

    Multi-Lane Transmitter (Tx) Testing
    ""

    USB4 Architecture defines two signaling lanes of 20 Gb/s. The LabMaster SDA 10 Zi-A provides acquisition, analysis, and compliance tests on both lanes simultaneously using SDAIII-CompleteLinQ Serial Data Analysis Software, significantly saving time in test setup, compliance, and debug. The WaveMaster SDA 8 Zi-B can be used to test the two lanes ‘lane-by-lane’ sequentially.

    Transmitter (Tx) Compliance Measurements
    ""

    QPHY-USB4-TX-RX uses clear connection diagrams to simplify all setup steps. Simply make the connections and select the measurements to be made. QPHY-USB4-TX-RX automatically performs all Tx compliance measurements.

    Receiver (Rx) Test Calibration
    ""

    Receiver test calibration is fully automated by QPHY-USB4-TX-RX. Here, QPHY controls the Anritsu MP1900A SQA and LabMaster SDA 10 Zi-A oscilloscope to calibrate the receiver stressed eye parameters. The Insertion Loss (IL) of the Total Channel must be calibrated and the cables to the oscilloscope (for both Tx measurements and Rx calibration) must be de-embedded using S-parameter measurements.

    USB4 S-Parameter Measurements
    ""

    As indicated by the connection diagrams in QPHY-USB4-TX-RX, Tx measurements and Rx calibration requires that insertion loss measurements of test cables and fixtures be made. The 4-port S-parameter model of the cables is measured and de-embed by the oscilloscope in all cases. During receiver calibration, the insertion loss of the USB-C cable and total test channel must also be measured. The WavePulser 40iX brings cost effective 40 GHz S-parameters, impedance profile measurements and analysis to the USB4 test bench.

    Receiver (Rx) BER Testing
    ""

    After the calibration is complete, the oscilloscope is replaced in the setup by the DUT (Device Under Test). BER (Bit Error Rate) testing is performed by reading the error registers in the DUTs receiver circuit for a specified observation time while the calibrated stressed eye signal is applied. The microcontroller polls the DUT error count register using SBTX/SBRX sideband signals through the USB-C Cable. QPHY-USB4-TX-RX supports automation of the BER testing and provides a full test report.

    QualiPHY
    ""

    QualiPHY is designed to reduce the time, effort and specialized knowledge needed to perform compliance testing on high-speed serial buses.

    • Guides the user through each test setup
    • Performs each measurement in accordance with the relevant test procedure
    • Compares each measured value with the applicable specification limits
    • Fully documents all results – Compliance Reports can be created as HTML, PDF, or XML.
    • QualiPHY helps the user perform testing the right way-every time!

    USB4 and Thunderbolt3 Test Fixtures (Ordered from Wilder-Tech)
    ""

    Go to www.wilder-tech.com for details on high speed test fixtures and DUT microcontrollers.

    USB4™, USB Type-C®, and USB-C® are trademarks of USB Implementers Forum.
    Thunderbolt™ is a trademark of Intel Corporation.

     

    ">
    主要特性
    • 支持 USB-C® 一致性测试规范:
      • USB4 Router组件
      • USB4 设备
      • Thunderbolt™ 3 主机/设备
      • USB4 Active Cable(CTS under development)
    • 支持的测试:
      • 发射机 (Tx) 测试
      • 接收机 (Rx) 测试
      • 使用 S 参数的 Rx 通道校准
      • 无源和有源电缆测量
    • 自动化测试 USB4 主机、设备、集线器、无源电缆和有源电缆组件
    • 多通道分析、合规性和调试 USB4 接口
    • 使用自动控制器和夹具控制被测设备 (DUT)
    • USB-C 电缆的插入损耗测量
    • QualiPHY 报告生成功能创建包含所有相关测试信息的综合报告

    QPHY-USB4-TX-RX 便捷一致性测试

    QPHY-USB4-TX-RX测试软件控制示波器、BERT和测试控制器对发射机(Tx)进行参数、抖动和眼图一致性测试; 校准受压眼图并在接收器 (Rx) 上执行 BER 测量。 它首先提供了如何连接测试系统以正确测试设备的分步指南。 然后它会自动配置仪器和 DUT 设置和功能,执行测试,并将结果记录在一致性测试报告中。

    多通道发射机 (Tx) 测试

    USB4 架构定义了两个 20 Gb/s 的信号通道。 这 LabMaster SDA 10 Zi-A 使用 SDAIII-CompleteLinQ 串行数据分析软件同时在两条通道上提供采集、分析和一致性测试,显着节省了测试设置、一致性和调试的时间。 WaveMaster SDA 8 Zi-B 示波器可以顺序测试两条通道的产品。

    发射机 (Tx) 一致性测量

    QPHY-USB4-TX-RX 使用清晰的连接图来简化所有设置步骤。 只需进行连接并选择要进行的测量即可。 QPHY-USB4-TX-RX 自动执行所有 Tx 一致性测量。

    接收机 (Rx) 测试校准

    接收器测试校准由 QPHY- 完全自动化USB4-TX-RX。 此处,QPHY 控制 Anritsu MP1900A SQA 和 LabMaster SDA 10 Zi-A 示波器校准接收器压力眼图参数。 必须校准总通道的插入损耗 (IL),并且必须使用 S 参数测量去嵌入示波器的电缆(用于 Tx 测量和 Rx 校准)。

    USB4 S 参数测量

    正如 QPHY 中的连接图所示-USB4-TX-RX、Tx 测量和 Rx 校准要求对测试电缆和夹具进行插入损耗测量。 在所有情况下,电缆的 4 端口 S 参数模型均由示波器测量和去嵌入。 在接收器校准期间,还必须测量 USB-C 电缆和总测试通道的插入损耗。 这 WavePulser 40iX 提供更具性价比 40 GHz S 参数、阻抗曲线测量和分析 USB4 测试方案。

    接收机 (Rx) BER 测试

    校准完成后,示波器在设置中被 DUT(被测设备)替换。 BER(误码率)测试是通过在指定的观察时间内读取 DUT 接收器电路中的错误寄存器来执行的,同时应用校准的压力眼图信号。 微控制器通过 USB-C 电缆使用 SBTX/SBRX 边带信号轮询 DUT 错误计数寄存器。 QPHY-USB4-TX-RX支持BER测试自动化,并提供完整的测试报告。

    QualiPHY

    QualiPHY 旨在减少在执行高速串行总线一致性测试上所需要的时间、精力,并提供专业知识辅导。

    • 指导用户完成每个测试设置
    • 按照相关的测试程序执行每次测量
    • 将每个测量值与相应的规格要求进行比较
    • 完整记录所有结果——合规报告可以创建为 HTML、PDF 或 XML格式。
    • QualiPHY 帮助用户每次都以正确的方式进行测试!

    USB4 和 Thunderbolt3 测试夹具(从 Wilder-Tech 订购)

    www.wilder-tech.com for details on high speed test fixtures and DUT microcontrollers." data-gt-human-content="true">在MyCAD中点击 软件更新 www.wilder-tech.com有关高速测试夹具和 DUT 微控制器的详细信息。

    USB4™、USB Type-C® 和 USB-C® 是 USB Implementers Forum 的商标。
    Thunderbolt™ 是英特尔公司的商标。

     

    WaveMaster 8000HD


      了解更多
    LabMaster 10 Zi-A 示波器